71(TVVB)
☆The long-term allowable working temperature of cable conductors should not exceed70℃, and the laying environment temperature should not be lower than 0℃.
☆The installation free suspension length shall not exceed 80m, and the movement speedshal not exceed 4m/s.
☆The allowable bending radius for cable laying and installation should not be less than 6times the small edge of the cable.
☆Executive standard:GB/5023.6-1997 and supplementary requirements
Keywords:
undefined3
undefined3
undefined3
undefined3
undefined3
Category:
Description
APPLICATION
This product is suitable for elevators and lifting machinery equipment with AC rated voltage of 300/500V(or450/750V)and below,and is used as a power connection line.
| Model | Rated voltage (V) | Number of cores | Nominal cross-section (mm2) |
| 227IEC71f(TVVB) | 300/500 | 3~24 | 0.75 |
| 227IEC71f(TVVB) | 450/750 | 3、4、5 | 0.75~25 |
| TVVB | 300/500 | 25~60 | 0.75、1 |